Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add filters








Language
Year range
1.
China Medical Equipment ; (12): 35-38, 2017.
Article in Chinese | WPRIM | ID: wpr-510287

ABSTRACT

Objective:To discuss the value of low dose scanning technique of 16-slice spiral CT for the diagnosis of pulmonary diseases.Methods: A retrospective analysis was adopted to analyze 43 image documents were scanned by 16-slice spiral CT and to evaluate their qualities.Results:All of patients were examined in accordance with the requirements and all of image qualities were more than good. Although their background noise were increased, the image quality did not affect the display of anatomical structure. Therefore, it can satisfy the requirements for the diagnosis of pulmonary diseases.Conclusion:The pulmonary multi-slice spiral CT based on low-dose scanning technology can improve the detection rate of lesions, reduce radiation dose for patients, prolong the service life of the tube and reduce the maintenance cost, therefore it is worthy for further promotion.

2.
China Medical Equipment ; (12): 86-89, 2017.
Article in Chinese | WPRIM | ID: wpr-509599

ABSTRACT

Objective:To investigate the significance of 3D printing technology in the treatment of skull base tumor.Methods: A 45-year-old male patient who felt headache and discomfort had progressive loss of vision to blindness in the left eye. Using MR plain scan found that there was a skull base tumor, so the patient was examined by brain CTA and 3.0T MR to obtain medical digital imaging of CT and MR and DICOM data which were input into computer for establishing three-dimensional model, and then printed it.Results: 3D reconstruction model can clearly display the anatomical structure of skull base tumor, three-dimensional space and peripheral blood around skull base tumor. Under the guidance of this new technology, the tumor was completely removed and the surrounding normal brain tissue was preserved as much as possible. The whole operation time was greatly reduced at the same time.Conclusion: The treatment of 3D printing technology is applied in skull base tumors can clearly display the anatomical structure, distinguish adjacent vessels around tumor; when it avoids missing tumor, also can more effectively assist preoperative planning, enhance the security for complex skull base surgery, accelerate the operation speed, improve operation accuracy; it has great application prospect in the precise treatment of neurosurgery.

3.
China Medical Equipment ; (12): 27-29,30, 2017.
Article in Chinese | WPRIM | ID: wpr-606149

ABSTRACT

Objective:To study and analyze the quality assurance(QA) and quality control(QC) in chest radiography based on X-ray digital radiography (DR).Methods:600 cases ( 320 male cases, 280 female cases, age range from 2 to 68 years old, with an average 48.2 years old) chest radiography based on DR were random sampling from database during the period from Oct., 2015 to Dec., 2015. In accordance with chest imaging criteria, these images were graded, and calculated the share rate. After analyzing the causes that produced the bad images, a number of measures were provided to improve the quality of image.Results:The patients can be examined in short time, and there are a large number of information with high resolution and rich layers. The qualified rate was 100% (Grade A with 525, accounting for 87.5%,Grade B with 63, accounting for 10.5%; Grade C with 12 , accounting for 2%), and the rate of waste film was zero.Conclusion: DR produced by computer digital image processing technology combined with X-ray radiation technology has powerful post-processing function. This function can combine a series of quality control measures to improve image quality as reducing radiation dosage, and finally, to realize the target of QA and QC.

4.
China Medical Equipment ; (12): 60-62, 2016.
Article in Chinese | WPRIM | ID: wpr-498649

ABSTRACT

Objective: To explore the application value of multi-slice spiral CT based on low dose technique in diagnosis of rib fracture. Methods: 58 patients with highly suspected rib fracture patients were examined by DR and multi-slice spiral CT. 3D reconstruction were finished after MSCT examination at the workstation, including MPR(multi-planar reconstruction), and volume rendering technique(VR). And the results were compared between DR and CT. Results:58 patients all successfully completed the chest X-ray film and multi-slice spiral CT examination. Multi-slice spiral CT image quality fully met the requirements of clinic. It can not only diagnose, but also display the number, location and morphology of rib fracture. 45 cases were diagnosed with chest DR rib fracture and suspected fracture, and the positive rate was 77.59%(45/58). 56 cases were definitely diagnosed with multi-slice spiral CT scanning and three-dimensional reconstruction rib fracture, and the positive rate was 96.55%. Conclusion: The patients can receive lower dose and the tube can be used for a longer time by low dose technique. 3D reconstruction techniques of multi-slice spiral CT not only improve the accuracy of diagnosis, but also display rib fracture morphology clearly, so its clinical value is much higher than DR.

5.
China Medical Equipment ; (12): 25-27,28, 2016.
Article in Chinese | WPRIM | ID: wpr-603963

ABSTRACT

Objective:To investigate the necessity and measures about quality assurance (QA) and quality control (QC) in bedside photography based on digital radiography (DR). Methods: To do retrospective analysis on bedside photography in the same month of different years (2013.9 and 2014.9) by image storage and PACS system. Each has 200 cases. They were evaluated and analyzed of its causes in order to explore the QA improvement measures.Results:The application of DR and its quality control in bedside photography can improve image quality obviously, shorten the examination time greatly, reduce radiation dose, put an end to waste film.Conclusion: DR has obvious advantages in the bedside photography, can provide better image with more information for clinic work.

6.
China Medical Equipment ; (12): 52-53,54, 2014.
Article in Chinese | WPRIM | ID: wpr-599352

ABSTRACT

Objective: To investigate the correlation between BMD based on DR and DEXA. Methods: A total of 30 cadaver hand specimens were measured by bone mineral density measurement software based on RA developed by us and Hologic QDR-2000. Results: The overall results of F test were significant so that the data were analyzed by SPSS16 statistical software(r=0.7798, P<0.05). It is moderately and highly correlated between RA and DEXA. Conclusion: Self-developed software has a bright future because it is accurate and cheaper compared to foreign software.

7.
Chinese Journal of Medical Physics ; (6): 1581-1582,1587, 2010.
Article in Chinese | WPRIM | ID: wpr-604995

ABSTRACT

Objective:To explore the imaging theory、Predominance and clinical applications of PET/CT.Methods:The definition of PET/CT was firstly explained in the paper.Then,we could learn not only the imaging theory and important parameters,but also predominance and clinical applications of PET/CT.Results:PET/CT can make the modality of PET and CT images,so that it is more widely used.Conclusion:PET/CT represents the highest level of medical imaging equipment nowadays,It is the ideal combination of the medical imaging diagnostic echnology.

8.
Chinese Journal of Medical Physics ; (6): 1504-1507, 2009.
Article in Chinese | WPRIM | ID: wpr-500230

ABSTRACT

Objective: To investigate the potential of gradient vector flow(GVF) Snake model as a method of image segment in radiographic absorptiometry method (RA) which is used to qualify bone mineral density. Methods: The Gradient Vector Flow model and the Region Growing method were applied in the segmentation of the middle phalanges image and aluminum wedge image separately in this paper. Then, the results can be compared. Results: The experiments shows that GVF Snake model is not only robust and practicable, but also segmentation results are in line with the actual border. Conclusions: GVF Snake model is very useful, and can be widely used in qualifying bone mineral density.

SELECTION OF CITATIONS
SEARCH DETAIL